Product Details
Animal medical ICU also can be called fully intelligent aerobic animal medical monitoring module.
The combination model of two independent control units with the upper and lower parts is suitable for more clinical applications in animal hospitals. Through compressor refrigeration and PTC heating, the temperature is controlled by air circulation mode, making the temperature in the cabin balanced and comfortable. At the same time, animal medical ICU is significant that the efficient dehumidification function creates a better medical environment. In addition, animal medical ICU is very effective for the treatment of respiratory diseases when it starts with a higher concentration of oxygen since it has a fast interface of atomization therapy instrument. The humanized human-computer interaction system brings great convenience to your operation. Such combination is suitable for animals with different sizes to be treated in the cabin.
Product parameters |
Product Model |
PAIM 5.0-1 |
display |
Type 8.4 W171XH128mm |
Input voltage |
AC100V/220V~ |
Touch screen |
Pointer film resistance type |
Frequency |
50/60 Hz |
Maximum power consumption |
1.3KW |
Temperature control mode |
2 chamber independent split cooling /PTC heating.
|
Average power consumption |
0.5KW(Rooms 3-4 are used independently) |
Weight |
234 kg |
Power failure security |
Emergency ventilation hatch with programmed control |
Appearance size |
122CM×73CM×157CM |
Negative ion purification function |
(7.2X106PCS/cm3X4)High concentration anion |
Air purification function |
Ultraviolet germicidal lamp;
High concentration anion air purification |
Standard spare parts |
Various hanging racks and animal sleeping baskets (optional) |
Conditions of use |
-10℃~40℃Environment (indoor) |
Ultraviolet sterilization |
UVC band 253nm, efficient ultraviolet sterilization system |
Set temperature |
15-38℃The temperature control accuracy±0.5℃ |
External humidifier |
Maximum atomization rate ≥ 0.2mL /min, fog particle (0.5-2um) noise ≤40dB(A)(optional) |
Set oxygen concentration |
21℃-60℃Control precision±1% |
LED light |
There are two ways of light control: warm light is divided into ten levels and its strength can be adjusted, and cold light is used for medical examination |
Alarm, warning |
Abnormal O2 concentration, temperature, sensor, and emergency hatch switch |
The fan control |
Automatic equalizing air supply |
Dehumidification indicators |
Automatic dehumidification system, standard humidity control at 40%, actual humidity control at < 50% |
|
|